Products
Home:Product >

Step-in VOC Environment Test Chamber

The step-in VOC environment test chamber is used to detect the release of harmful substances such as volatile organic compounds (VOCs), formaldehyde in furniture, carpets, toys, musical instruments, decoration and decoration, building materials and so on. Especially for products placed densely, space closed indoor, car, cumulative concentration will be higher, greater health hazards.

Detailed
Brand:Jiuban
Model:JB-50
Name:Walking-in VOC Environment Test Chamber
一、Purpose:
  The step-in VOC environment test chamber is used to detect the release of harmful substances such as volatile organic compounds (VOCs), formaldehyde in furniture, carpets, toys, musical instruments, decoration and decoration, building materials and so on. Especially for products placed densely, space closed indoor, car, cumulative concentration will be higher, greater health hazards.
二、Implementation criteria:
GB18584《Limitation of harmful substances in wood furniture》Latest Revision
HJ 571-2010《Technical Requirements for Environmental Marking Products Wood-based Panels and Their Products》
ISO 16000-9-2006《Determination of Volatile Organic Compounds Released from Building Products and Furniture》
ASTM D 6670-01《Standard operation for determination of VOCs release from indoor materials and products by full scale environmental chamber》
EN717-1《Environmental box method for formaldehyde emission measurement of wood-based panels》
ASTMD E1333-02《Standard Test Method for Determining Formaldehyde Concentration in Wood Products Released Gases by Large Scale Environment Box》
EN13419-1《Building Products - Determination of VOCs Release Part 1: Release Test Environment Box Method》
三、Product parameters:
project
parameter
Cabin volume
2-50m³±2%
temperature range 15~40℃;±0.5℃
Humidity range 30%-70%RH;±2.0%RH
Temperature and humidity uniformity
≤±0.8℃;≤±2%RH
Highly clean 120±2℃
Air exchange rate
0.2-2.5,±3%
Air velocity
0.1-0.5m/s
Background concentration of formaldehyde
≤0.006mg/m³
TVOCconcentration
≤0.02mg/m³
IndividualVOCconcentration
≤0.002mg/m³
Cleanliness
Particulate matter with diameter greater than 0.5UM≤100particles/m³
Air tightness
Under 1000PA external pressure, the static leakage rate is less than or equal to the tank capacity.*0.5×10-3m³/min
Toluene recovery
≥80%
Working power supply
380V,50HZ
Equipment noise value
≤70dB
weight 350KG
About us
Company Profile
Company honor
Corporate culture
Contact us
Products
universal testing machine
more
Customer
Selected partners
News
Company news
Industry information
Technical proposal
Contact us
Contact information
Copyright 2018-2019 © All Right Reserved. JIUB